USS-SC100A-TM-O
USS-SC100A-TM-O – Thermopile principle, when the human body (wrist, forehead) is actively measuring the temperature, the screen displays the body temperature, if it exceeds 37.3 °, it will sound an alarm and record the alarm number.
DESCRIPTION
USS-SC100A-TM-O –Thermopile principle, when the human body (wrist, forehead) is actively measuring the temperature, the screen displays the body temperature, if it exceeds 37.3 °, it will sound an alarm and record the alarm number.
Model |
USS-SC100A-TM-O |
Display content | When the temperature is measured, the temperature display area shows the actual temperature the number of alarm. When the running indicator is green, it is ready to operate. When the alarm light turns red, a temperature exceeding the threshold is detected or metal objects are detected. The signal indicator indicates the presence or absence of interference in zones 1-18 from bottom to top. The signal light can show the detected objects’ metal content, the more metal in the item, the brighter the alarm light. |
Temperature detection range | 35℃~42℃ |
Temperature error | ±0.5℃ |
Accuracy | 0.02℃ |
Metal detection zone mode | 18 metal detection areas |
Metal detection accuracy | With the function of adjusting sensitivity, each location can set the sensitivity of 200 levels (0~200), the smallest metal object size that can be detected is 30mm*30mm*2mm. |
Password protection | Only authorized personnel can operate. |
Power supply | AC220V/50HZ |
Power consumption | <20W |
Operating temperature | 10℃~45℃ |
Operating humidity | <80% RH |
Weight | 45KG |
Overall dimension | 2270mm*830mm*500mm |
Channel dimension | 2000mm*700mm*500mm |
Notes | The installation environment should be rainproof, moisture-proof and dry, and the environment temperature balance should be kept as far as possible. High temperature objects and large metal item should be kept away from the security gate. Chemical agents such as 84 disinfectant and 75% ethanol disinfectant should be avoided from corroding the outer membrane of the temperature control probe. |
- Multi-function, supports temperature measurement and metal detection
- Quick and easy to use placement
- Different high temperature detection sensors used on both sides, easy to measure measuring
- Temperature Distance: 2-5cm, error <0.5 ℃
- Non-contact detection to avoid infection cross
- Avoid leakage manual temperature measurement when the flow is large
- Editable temperature alarm: alarm will be triggered when the detected temperature exceeds the set value
- Through working environment temperature measurement, flexible temperature compensation adjustment, improve detection accuracy
- 18 different metal detection areas that can indicate with precise contraband metal